This is a sample report for a synthetic property — not a real inspection. Start your own free trial
Sample Home Inspections
Inspection Report
Property
4521 Maple Drive
Pleasant Hill, IA 50327
February 12, 2026
Client: Taylor Buyer
Inspector: Jordan Reyes
2,200 sq ftBuilt 19984 bed2.5 bathbasement

Summary of Findings

4
Safety Hazards
1
Major Defects
4
Minor Defects
3
Maintenance
Invoice
Roof CoveringDeficientMajor Defect

Architectural shingles, approximately 18-20 years old. Multiple areas of concern observed.

Significant granule loss and curling observed on the south-facing slope. Several shingles are lifting at the tabs. Roof covering is approaching end of expected service life and should be budgeted for replacement within 2-3 years.

Roof Component Anatomy
Roof Component Anatomy

Cross-section showing ridge, hip, valley, rake, eave, soffit, fascia, drip edge, underlayment, decking, and shingle layers.

FlashingDeficientMinor Defect

Step flashing at chimney and sidewall intersections.

Missing kick-out flashing at the lower right corner of the chimney-to-sidewall intersection. This can direct water behind the siding. Recommend installing kick-out flashing to prevent moisture intrusion.

Flashing Details
Flashing Details

Step flashing, counter flashing, valley flashing, and chimney flashing installation details.

Gutters & DownspoutsSatisfactory

Aluminum gutters in serviceable condition. Downspouts discharge at appropriate distance from foundation.

Roof PenetrationsSatisfactory

Plumbing vent boots and exhaust caps in good condition. Sealant intact.

Siding & TrimSatisfactory

Vinyl siding in good condition. No visible damage or moisture penetration.

Windows & DoorsDeficientMaintenance

Double-pane vinyl windows throughout.

Failed window seal (fogging between panes) observed at the master bedroom window on the west side. Window is functional but the seal failure reduces energy efficiency. Monitor or replace when convenient.

Window Installation Detail
Window Installation Detail

Proper window installation showing flashing tape, sill pan, head flashing, caulk/sealant, and weep holes.

Foundation VisibleSatisfactory

Poured concrete foundation. Minor hairline cracks consistent with normal settling. No structural concerns.

Foundation Types
Foundation Types

Comparison of full basement, crawlspace, and slab-on-grade foundations with key inspection points for each.

Grading & DrainageDeficientMinor Defect

Grade and drainage around the foundation perimeter.

Negative grade observed along the north side of the foundation, approximately 8 feet in length. Soil slopes toward the foundation wall. Recommend regrading to achieve positive drainage (6 inches of fall in the first 10 feet) to prevent water pooling at the foundation.

Grading & Drainage
Grading & Drainage

Proper grading (6 inches in 10 feet from foundation), downspout extensions, swales, and French drain placement.

Main PanelDeficientSafety Hazard

200-amp Siemens panel in basement utility room.

Double-tapped breaker observed at two 20-amp circuits. Two conductors are connected to a single breaker terminal that is rated for only one conductor. This is a fire hazard. Recommend evaluation and correction by a licensed electrician.

Double-tapped breakerBasement utility roomDefectSafety Hazard

Two 20-amp circuits share a single breaker terminal rated for one conductor.

Recommendation

Recommend evaluation and correction by a licensed electrician.

Panel Wiring Diagram
Panel Wiring Diagram

Main breaker panel layout showing bus bars, neutral/ground bars, branch circuits, AFCI/GFCI breakers, and proper wire sizing.

Branch WiringSatisfactory

Copper NM-B (Romex) wiring throughout. All junction boxes covered. Grounding appears proper at accessible outlets tested.

Reversed polarityGarageDefectMinor Defect

One outlet in the garage tested with reversed polarity (hot/neutral reversed).

Recommendation

Recommend correction by a licensed electrician.

GFCI ProtectionDeficientSafety Hazard

Tested GFCI outlets in kitchen, bathrooms, garage, and exterior.

Missing GFCI protection at the garage outlet. This outlet is within 6 feet of the utility sink and in a potentially wet location. GFCI protection is required by current electrical codes. Recommend installation of GFCI outlet or breaker by a licensed electrician.

GFCI/AFCI Protection Zones
GFCI/AFCI Protection Zones

Floor plan showing which rooms and areas require GFCI vs AFCI protection per NEC requirements.

Water HeaterDeficientMaintenance

50-gallon gas water heater, manufactured 2012.

Water heater is approximately 14 years old, approaching the end of typical 12-15 year service life for a residential gas unit. No active leaks or corrosion observed. TPR valve and discharge pipe are properly installed. Recommend budgeting for replacement in the near term.

Water Heater Components
Water Heater Components

Tank water heater showing TPR valve, discharge pipe, anode rod, dip tube, flue, thermocouple, and gas valve.

Supply LinesSatisfactory

Copper supply lines. Good water pressure at all fixtures tested. No visible leaks at accessible connections.

Supply Line Layout
Supply Line Layout

Residential water supply system from main shutoff through distribution. Hot and cold lines, fixture shutoffs, and pipe materials.

Drain LinesSatisfactory

PVC drain lines. All drains functional with appropriate flow rate. No visible leaks.

Fixtures & FaucetsSatisfactory

All faucets operational. Toilets flush properly. No leaks at supply connections.

FurnaceSatisfactory

80,000 BTU gas furnace, approximately 8 years old. Fired and operated normally during inspection. Filter recently replaced.

Forced Air System
Forced Air System

Complete forced-air heating/cooling system: furnace, A/C condenser, evaporator coil, supply/return ducts, registers, filter, and thermostat.

Air ConditioningSatisfactory

Central AC unit. Operated normally with appropriate temperature differential (18°F) at supply and return registers.

DuctworkDeficientMaintenance

Flexible ductwork in attic space.

Disconnected duct run observed in the attic above the second-floor hallway bathroom. This vent is not delivering conditioned air to the room. Recommend reconnection by an HVAC technician.

Walls & CeilingsDeficientMinor Defect

Drywall throughout. Painted surfaces.

Water staining observed on the ceiling in the upstairs hallway, approximately 12 inches in diameter. Stain appears old and dry. Recommend monitoring for recurrence. The source may be related to the disconnected duct run above (condensation) or a past roof leak.

FloorsSatisfactory

Hardwood on main level, carpet on upper level, tile in bathrooms. All in serviceable condition. No significant unevenness or damage.

Stairs & RailingsSatisfactory

Stairs and railings secure. Balusters properly spaced. No safety concerns.

Stair Code Dimensions
Stair Code Dimensions

IRC stair requirements: max 7-3/4 inch rise, min 10-inch tread, 34-38 inch handrail height, 36-inch width, and 6'8" headroom.

Smoke & CO DetectorsDeficientSafety Hazard

Checked smoke and CO detectors in all required locations.

Missing carbon monoxide detector on the upper level. Local code requires CO detectors within 15 feet of every bedroom. The upper level has three bedrooms with no CO detector present. Recommend immediate installation of a CO detector in the upper level hallway.

Standards of Practice

This inspection was performed in general accordance with state standards of practice for home inspectors. It is a visual survey of readily accessible areas and systems and is not technically exhaustive.

22 items inspected.

This report was generated by Sample Home Inspections. For questions about the findings, please contact your inspector.